Index

Carrier fluid concentration

Ver: 0
 

DESCRIPTION

Allows the user to modify the current value of the carrier fluid concentration c(T) used in mass transfer problem. c(T) is defined as

c(T) = r0(T) / Mw = Po / Rg * T

where r0(T) is the density of carrier fluid (perfect gas), Mw is molecular weight of carrier fluid, Po is the operating pressure of reactor, Rg is the gas constant and T is the temperature mesured in K?.

By default, Po = 1.0132500E+05 Pascal and Rg = 8.3143000.

 
OPTIONS
 
-1 Upper level menu
The current values are accepted
1 Modification of Po
The value of Po is modified
2 Modification of Rg
The value of Rg is modified
NOTES The units for the parameters are :
 
Parameter
Mass
Length
Time
Temperature
Mole
    c(T)
-
-3
-
-
1
    Po
1
-1
-2
-
-
    Rg
1
2
-2
-1
-1
    T
-
-
-
1
-


SEE ALSO

  • mass transport equations (UM)
  • create a new task
  • system of units
  • material data
  • density